- Products
Operation:
When de-energized, the valve blocks flow in both directions. When energized, the cartridge’s spool shifts to allow flow in both directions.
Operation of manual override option:
To override, push button in, twist counterclockwise 180° and release. In this position, the valve will remain open in a detented condition. To return to normal operation, push button in, twist clockwise 180° and release. Override will be detented in this position.
Specifications
Max. operating pressure: |
240 bar |
Flow: |
See pressure drop vs. flow graph |
Internal leakage: |
7 Drops/min. max. at 240 bar |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Coil duty rating: |
Continuous from 85% to 115% of nominal voltage |
Fluids: |
Mineral-based fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY12-2, see page H.1.5 |
Body material: |
Steel & ductile iron rated to 350 bar |