Operation:
When de-energized, the HY-SP-08-21 allows flow from ② to ①. When the valve is partially energized, the valve begins to throttle the flow from ② to ①. When fully energized, the poppet closes on the seat, blocking flow from ② to ①. Flow from ① to ② will occur when hydraulic pressure exceeds the solenoid force.
Technical specification (for application beyond these parameters, please contact with us)
Model |
HY-SP08-21 |
Installation position |
Unlimited |
Storage temperature (℃) |
-20℃ to +55℃ |
Ambient temperature (℃) |
-20℃ to +50℃ |
Hydraulic specification
Operating pressure |
207 Bar (3000psi) |
Flow |
0 to 22.7 Lpm (0 to 6 gpm) |
Minimum operating dither/ pulse frequency |
70 Hz |
Hydraulic fluid |
Mineral oil, phosphate-ester |
Fluids |
7.4 ~ 420 cSt (50 ~ 2000 sus) |
Temperature |
-40℃~+140℃, with NBR seals |
Cavity |
HY08-2, see page H.1.2 |
Internal leakage |
5 Drops/minute max. at 207 bar (3000psi) |
Electrical specification
Max. Control current |
12 VDC coils: 1.0 ± 0.1A; 24 VDC coils: 0.5 ± 0.05A |