Operation:
On no remote pilot signal at ①, the valve allows flow from ③ to ② bi-directional, while flow is blocked at ④, spring chamber vent-to-atmosphere, which is internally O-ring sealed from the cartridge flow paths.
On remote pilot signal at ①, the valve shifts to open ③ to ④, while blocking flow at ②. Because of the vented spring chamber, the cartridge may be fully pressurized at any port without affecting required pilot pressure.
Specifications
Max. operating pressure: |
240 Bar |
Flow: |
See pressure drop vs. flow graph |
Internal leakage: |
82 cc/min.max. at 207 bar |
Pilot pressure required: |
To spool crossover 7.6 bar (110psi) To full spool shift 8.6 bar (125psi) |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Fluids: |
Mineral-based fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY10-4, see page H.1.4 |
Body material: |
6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar |