Operation:
In its steady-state, spring-offset position, the valve directs flow from ③ to ②, and from ④ to ①. In the actuated (pulled) position, the cartridge directs flow from ③ to ④, and from ② to ①. The spring chamber is vented at ①.
Note: pressure at port ① will directly act on the spool and spring. Port ① is intended to be a tank port only. Series operation is prohibited due to the tank port ① pressure rating.
A unique pull-and-rotate feature for holding the positive actuated position is optional.
A 90° rotation is required to position at the hold slot. The valve resets to spring-return de-actuated with a slight pull and a 90° turn from the locked actuated position.
Specifications
Operating pressure: |
Port ②, ③ and ④ (on ②, ③ and ④): 240 bar |
Port ① max pressure (on ① max.): max. at 14 bar |
|
Flow: |
See pressure drop vs. flow graph |
Internal leakage: |
82 cc/min.max. at 240 bar |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Fluids: |
Mineral-based fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY08-4, see page H.1.3 |
Body material: |
6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar |