- Products
Operation:
The valve blocks flow ② to ① until an operator pulls the shaft outward.
A unique pull-to-rotate feature for holding the positive actuated position is optional.
A 90° rotation is required to position at the hold slot. The valve resets to spring-return de-actuated with a slight pull and a 90° turn from the locked actuated position.
Specifications
Max. operating pressure: |
240 Bar |
Flow: |
See pressure drop vs. flow graph |
Internal leakage: |
5 Drops/min.max. at 207 bar |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Fluids: |
Mineral-based fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY08-2, see page H.1.2 |
Body material: |
6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar |